Global thermal pollution of rivers from thermoelectric power plants
Worldwide riverine thermal pollution patterns were investigated by combining mean annual heat rejection rates from power plants with once-through cooling systems with the global hydrological-water temperature model variable infiltration capacity (VIC)-RBM. The model simulates both streamflow and water temperature on 0.5° × 0.5° spatial resolution worldwide and by capturing their effect, identifies multiple thermal pollution hotspots.